home *** CD-ROM | disk | FTP | other *** search
/ Spec Disk 1998 Spring 4.0 / Spec Disk 1998 Spring 4.0.iso / text / 07435seq.txt < prev    next >
Encoding:
Text File  |  1998-06-22  |  6.0 KB  |  193 lines

  1.                          SECTION 07435
  2.  
  3.                    LIGHT TRANSMITTING PANELS
  4. NOTE ** This section is based on products manufactured by
  5.         Sequentia Incorporated, at the following address:
  6. NOTE **      4545 Pine Timbers
  7. NOTE **      Suite 320
  8. NOTE **      Houston, TX  77041
  9. NOTE **      Tel:  800-231-4565 (800-833-8355, Texas)
  10. NOTE **      Fax:  713-462-3530
  11.  
  12. NOTE ** Sealbrite insulated plastic skylight domes are
  13.         factory bonded to flat architectural standing seam
  14.         roof panels used on the balance of the project.
  15.         Some minor rib configurations also can be
  16.         accommodated.  Contact your Sequentia
  17.         representative before selecting a structural
  18.         standing seam roof panel system to assure
  19.         compatibility with the Sealbrite daylighting
  20.         technique.
  21. NOTE **
  22. NOTE ** SECTION 07435 - LIGHT TRANSMITTING PANELS,
  23.         Copyright 1998, The Architect's Catalog, Inc.
  24.  
  25. PART 1  GENERAL
  26.  
  27. 1.1 SECTION INCLUDES
  28.  
  29.     A.  Insulated plastic skylight domes installed in metal
  30.         roofing.
  31.  
  32. 1.2 RELATED SECTIONS
  33. NOTE ** Delete any sections below not relevant to this
  34.         project;  add others as required.
  35.  
  36.     A.  Section 07610 - Sheet Metal Roofing.
  37.  
  38. 1.3 REFERENCES
  39. NOTE ** Delete references from the list below that are not
  40.         actually required by the text of the edited
  41.         section.
  42.  
  43.     A.  ASTM D 635 - Standard Test Method for Rate of Burning
  44.         and/or Extent and Time of Burning of Self-Supporting
  45.         Plastics in a Horizontal Position.
  46.  
  47.     B.  ASTM D 1003 - Standard Test Method for Haze and Luminous
  48.         Transmittance of Transparent Plastics.
  49.  
  50.     C.  ASTM D 1929 - Standard Test Method for Ignition
  51.         Properties of Plastics.
  52.  
  53.     D.  ASTM E 84 - Standard Test Method for Surface Burning
  54.         Characteristics of Building Materials.
  55.  
  56.     E.  ASTM E 283 - Standard Test Method for Determining the
  57.         Rate of Air Leakage Through Exterior Windows, Curtain
  58.         Walls, and Doors Under Specified Pressure Differences
  59.         Across the Specimen.
  60.  
  61.     F.  ASTM E 330 - Standard Test Method for Structural
  62.         Performance of Exterior Windows, Curtain Walls, and Doors
  63.         By Uniform Static Air Pressure Difference.
  64.  
  65.     G.  ASTM E 331 - Standard Test Method for Water Penetration
  66.         of Exterior Windows, Curtain Walls, and Doors by Uniform
  67.         Static Air Pressure Difference.
  68.  
  69.     H.  Uniform Building Code Standards.
  70.  
  71. 1.4 PERFORMANCE REQUIREMENTS
  72.  
  73.     A.  Air Infiltration (ASTM E 283):  Less than 0.01 CFM at
  74.         6.24 psf.
  75.  
  76.     B.  Water Penetration (ASTM E 331):  No water penetration at
  77.         6.24 psf.
  78.  
  79.     C.  Total Imposed Load (ASTM E 330):  0.85 inch deflection,
  80.         no failure at 120 psf (5-foot purlins).
  81.  
  82.     D.  Uplift (ASTM E 330):  0.060 inch deflection, no failure
  83.         at 60 psf (5-foot purlins).
  84.  
  85. 1.5 SUBMITTALS
  86.  
  87.     A.  Submit under provisions of Section 01300.
  88.  
  89.     B.  Product Data:  Provide manufacturer's standard details
  90.         and catalog data demonstrating compliance with referenced
  91.         standards.
  92.  
  93.     C.  Shop Drawings:  Submit for approval the following:
  94.         1.  Drawings showing skylight layout within panels, and
  95.             overall skylight arrangement on roof.
  96.  
  97. 1.6 DELIVERY, STORAGE, AND HANDLING
  98.  
  99.     A.  Store products indoors and protect from moisture,
  100.         construction traffic, and damage.
  101.  
  102.  
  103. PART 2  PRODUCTS
  104.  
  105. 2.1 MANUFACTURER
  106.  
  107.     A.  Provide insulated plastic skylight domes factory bonded
  108.         to metal roof panels by Sequentia Incorporated; 4545 Pine
  109.         Timbers; Suite 320; Houston, TX 77041.  ASD. Tel: (800)
  110.         231-4565 (800-833-8355, Texas), Fax: (713) 462-3530.
  111.  
  112.     B.  Substitutions will not be permitted.
  113.  
  114. 2.2 FABRICATED UNITS
  115.  
  116.     A.  "Sealbrite" insulated plastic domes, factory-bonded to
  117.         architectural metal roof panels.
  118.  
  119. 2.3 MATERIALS
  120. NOTE ** Select either acrylic or polycarbonate domes,
  121.         below.
  122.  
  123.     A.  Acrylic plastic:
  124.         1.  Flame spread (ASTM E 84):  140.
  125.         2.  Smoke developed (ASTM E 84):  385.
  126.         3.  Burning rate (ASTM D 635):  Less than 1.5 inches per
  127.             minute.
  128.         4.  Ignition point (ASTM D 1929):  750 degrees F.
  129.         5.  R-value of dome:  2.5.
  130.         6.  Glazing class (UBC Std. 52-4):  CC 2.
  131.  
  132.     B.  Polycarbonate plastic.
  133. NOTE ** Delete colors, below, that are not required.
  134.  
  135.     C.  Color:  Clear.
  136.         1.  Light transmission (ASTM D 1003):  85 percent.
  137.  
  138.     D.  Color:  White.
  139.         1.  Light transmission (ASTM D 1003):  52 percent.
  140.  
  141.     E.  Color:  Gray.
  142.         1.  Light transmission (ASTM D 1003):  26 percent.
  143.  
  144.     F.  Color:  Bronze.
  145.         1.  Light transmission (ASTM D 1003):  25 percent.
  146.  
  147. 2.4 FABRICATION
  148.  
  149.     A.  Fabricate domes in sizes indicated.
  150. NOTE ** Maximum opening size is shown below.  Edit if other
  151.         opening sizes are required.
  152. NOTE **
  153. NOTE ** Panels must be between 16 and 24 inches wide, and 5
  154.         and 40 feet in length.  Standard 10 foot panels are
  155.         preferred.
  156.         1.  Opening size:  11 x 48 inches.
  157.  
  158.     B.  Form insulated domes with interior dome and exterior dome
  159.         encapsulating dead air space.
  160.  
  161.     C.  Bond domes under factory conditions to metal roof panels
  162.         specified elsewhere in Division 7.
  163.         1.  Seal domes to metal roof panels.
  164.         2.  Provide weep path.
  165.         3.  Secure with chemically bonded anodized aluminum
  166.             retainer.
  167.  
  168.  
  169. PART 3  EXECUTION
  170.  
  171. 3.1 EXAMINATION
  172.  
  173.     A.  Verify that construction is completed, approved, and
  174.         ready to receive roof panels.
  175.  
  176.     B.  Correct any deficiencies before installing panels.
  177.  
  178. 3.2 INSTALLATION
  179.  
  180.     A.  Lay out domed roof panels in accordance with approved
  181.         drawings.
  182.  
  183.     B.  Install panels in accordance with panel installation
  184.         requirements specified elsewhere in Division 7.
  185.  
  186. 3.3 ADJUST AND CLEAN
  187.  
  188.     A.  Remove scraps and debris from the project site, and leave
  189.         in clean condition.
  190.  
  191.  
  192.                          END OF SECTION
  193.